Double Stage High Pressure Gas Boosters for CNG Pipelines Testing

Double Stage High Pressure Gas Boosters for CNG Pipelines Testing

STT series Gas Boosters are double acting, double stage models with single air drive head. Gas inlet pressure is from 1 bar (14.5psi) to 10 bar (145 psi). Provide for pressures up to 80MPa.

Technical Parameters of STT Series Gas Boosters:

TypePressure  ratioMin.   gas inlet pressurePA(bar)Max.   gasInletpressurePA(bar)Max.gas  outlet  pressure  PB(bar)Formula   tocalculate   gasoutlet   pressurePBConnection:Gas   Inlet /Gas   outlet(NPT tread)Max.   flow at air drive pressure of 6 bar (L/min)
STT2525:10.11020025XPL+3.5XPA1/4/ 1/4136(at   PA of 8 bar )
STT4040:10.11032040XPL+   6XPA1/4/ 1/4124(at   PA of 8 bar )
STT10/6010:1/60:10.11048060XPL+6X   PA1/4/ 1/484(at   PA of 8 bar )
STT25/6025:1/60:1102548060XPL+2.5XPA1/4/ 1/480(at   PA of 15 bar )
STT100100:10.110800100XPL+10XPA3/8/ M14X1.563(at   PA of 8 bar )

Note:  PL: air drive pressure    PA: gas inlet pressure   PB: gas outlet pressure