Portable Double Stage Gas Booster
SHINEEAST PST Series Gas Boosters are double acting, double stage models with single air drive head, with diameter of drive plunger 125mm.
Gas inlet pressure is from 0.2 bar (2.90 psi) to 10 bar (145 psi).
Technical parameters of PST Series Gas Boosters:
Type | Pressureratio | Min. gas inlet pressure PA (bar) | Max. gas inlet pressurePB (bar) | Max.outlet pressure PB (bar) | Formula to calculate gas outlet pressure PB | Connection:Gas Inlet /:Gas outlet(NPT thread) | Max. Flow atair drivepressure of6bar in L/min | |
PST25 | 25:1 | 0.2 | 10 | 200 | 25PL+3.5PA | 1/4/1/4 | 83(at PA of 8 bar ) | |
PST40 | 40:1 | 0.2 | 10 | 320 | 40PL+6PA | 1/4/1/4 | 75(at PA of 8 bar ) | |
PST60 | 60:1 | 0.2 | 10 | 480 | 60PL+6PA | 1/4/1/4 | 51(at PA of 8 bar ) | |
PST100 | 100:1 | 0.2 | 10 | 800 | 100PL+10PA | 1/4/1/4 | 38(at PA of 8 bar ) |
PST100 | 100:1 | 0.2 | 10 | 800 | 100PL+10PA | 1/4/1/4 | 38(at PA of 8 bar ) |
Note: PL: air drive pressure PA: gas inlet pressure PB: gas outlet pressure